Equipment: Vertical coil type thermic fluid heaters / thermal fluid heaters
Equipment Type: Heat-Transfer Equipment -> Heater
Unit Type:
Technical Parameters:
Post Time: 2010-06-30
Main Features:
Usage:
Description: High operating temperatures (up to 300°C) with low system pressure Robust & reliable with minimum maintenance for burner, pump & controls Simple circuit, no blow downs, steam traps or condensate return systems necessary when compared with a steam system Combined expansion / de-aeration tank simplifies piping work, protects thermic fluid from oxidation & provides continuous de-aeration of thermic fluid thereby avoiding pump cavitation Three pass design Pre-heated combustion air is an integral part of the design giving superior thermal efficiency Output range from 50000 kcal/hr to 1000000 kcal/hr Fully automatic, oil, gas or dual fuel burners; ON - OFF or with modulating mechanism Flame failure safety Thermic fluid low flow tripping safety Overriding temperature tripping safety Fail safe instrumentation Control circuit logic ensures the heater going to lock out safety in case of any abnormal operating condition as well as monitors any instrument''s failure Audio visual annunciation on control panel gives guidelines to troubleshoot unsafe operating conditions